12VDC piling cap calculator for Single Color and Color Changing RGBW systems.
Recommended: center feed. Can be powered from one end, but larger wire may be required due to voltage drop.
Install the power supply box above the waterline, under the dock or on the inside of a piling, protected from direct spray, and accessible for service.
Recommended: center feed. Can be powered from one end, but larger wire may be needed.
Power from the main trunk, then split left and right at the top.
Treat as three sections: left side, back section, and right side.
Best box location is the inside corner where the two sections meet.
Planning guide only. Final wire size should be verified based on exact routing, fixture specs, and site conditions.
| Current | 25 ft | 50 ft | 75 ft | 100 ft | 150 ft | 200 ft |
|---|---|---|---|---|---|---|
| 5A | 12 AWG | 10 AWG | 8 AWG | 6 AWG | 4 AWG | 2 AWG |
| 10A | 10 AWG | 8 AWG | 6 AWG | 6 AWG | 4 AWG | 2 AWG |
| 15A | 8 AWG | 6 AWG | 4 AWG | 4 AWG | 2 AWG | 1/0 AWG |
| 20A | 6 AWG | 4 AWG | 2 AWG | 2 AWG | 1/0 AWG | 2/0 AWG |
| 25A | 4 AWG | 4 AWG | 2 AWG | 1/0 AWG | 2/0 AWG | 3/0 AWG |
| 30A | 4 AWG | 2 AWG | 1/0 AWG | 2/0 AWG | 3/0 AWG | 4/0 AWG |
| 40A | 2 AWG | 1/0 AWG | 2/0 AWG | 3/0 AWG | 4/0 AWG | Review Design |
This calculator is for planning and estimating only. Final system design should be verified based on actual fixture specifications, exact wire routing, local electrical code, and site conditions.